3RT1046-1AG20
3RT1046-1AG20 - siemens
Power contactor, AC-3 95 A, 45 kW / 400 V 110 V AC, 50/60 Hz 3-pole, Size S3 Screw ter..
in stock:3
Description:
The 3RT1046-1AG20 is a power contactor designed for AC switching, with a rated control supply voltage of 110V at both 50Hz and 60Hz. This power contactor is rated for a maximum operation power of - kW according to NEMA standards. The voltage type for actuating is AC, making it suitable for a variety of industrial and commercial applications. This product is classified under ETIM category EC000066 - Power contactor, providing a reliable and efficient solution for controlling power circuits. With its high-quality design and performance capabilities, the 3RT1046-1AG20 ensures smooth and reliable operation in demanding environments.
Low-voltage industrial components > Power contactor, AC switching
CONTROL AND CONTACTORS > Contactors for switching motors
General technical data
Size of contactor S3 ● Insulation voltage rated value 1 000 V Degree of pollution 3 Surge voltage resistance rated value 6 kV maximum permissible voltage for safe isolation ● between coil and main contacts acc. to EN 60947-1 690 V ● protection class IP on the front IP20; IP20 on the front with cover / box terminal ● Protection class IP of the terminal IP00 Shock resistance at rectangular impulse ● at AC 6,8g / 5 ms, 4g / 10 ms Shock resistance with sine pulse ● at AC 10,6g / 5 ms, 6,2g / 10 ms Mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added electronics-compatible auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 Reference code acc. to DIN EN 81346-2 Q Ambient conditions Installation altitude at height above sea level ● maximum 2 000 m Ambient temperature ● during operation -25 ... +60 °C ● during storage -55 ... +80 °C Main circuit
Number of poles for main current circuit 3 Number of NO contacts for main contacts 3 Number of NC contacts for main contacts 0 Operating current ● at AC-1 at 400 V — at ambient temperature 40 °C rated value 120 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 120 A — up to 690 V at ambient temperature 60 °C rated value 100 A — up to 1000 V at ambient temperature 40 °C rated value 70 A — up to 1000 V at ambient temperature 60 °C rated value 60 A ● at AC-3 — at 400 V rated value 95 A — at 690 V rated value 58 A — at 1000 V rated value 30 A ● at AC-4 at 400 V rated value 80 A Connectable conductor cross-section in main circuit at AC-1 ● at 60 °C minimum permissible 35 mm² ● at 40 °C minimum permissible 50 mm² Operating current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 42 A ● at 690 V rated value 27 A Operating current ● at 1 current path at DC-1 — at 24 V rated value 100 A — at 110 V rated value 9 A ● with 2 current paths in series at DC-1 — at 24 V rated value 100 A — at 110 V rated value 100 A ● with 3 current paths in series at DC-1 — at 24 V rated value 100 A — at 110 V rated value 100 A Operating current ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 40 A — at 110 V rated value 2.5 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 100 A — at 110 V rated value 100 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 100 A — at 110 V rated value 100 A Operating power ● at AC-1 — at 230 V at 60 °C rated value 38 kW — at 400 V rated value 66 kW — at 690 V rated value 114 kW — at 690 V at 60 °C rated value 114 kW — at 1000 V at 60 °C rated value 98 W ● at AC-2 at 400 V rated value 45 kW ● at AC-3 — at 230 V rated value 22 kW — at 400 V rated value 45 kW — at 500 V rated value 55 kW — at 690 V rated value 55 kW — at 1000 V rated value 37 W Operating power for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 22 kW ● at 690 V rated value 25.4 kW Thermal short-time current limited to 10 s 760 A No-load switching frequency ● at AC 5 000 1/h Operating frequency ● at AC-1 maximum 900 1/h ● at AC-2 maximum 350 1/h ● at AC-3 maximum 850 1/h ● at AC-4 maximum 250 1/h Auxiliary circuit
Number of NC contacts for auxiliary contacts ● instantaneous contact 0 Number of NO contacts for auxiliary contacts ● instantaneous contact 0 Operating current at AC-12 maximum 10 A Operating current at AC-15 ● at 230 V rated value 6 A ● at 400 V rated value 3 A Operating current at DC-12 ● at 60 V rated value 6 A ● at 110 V rated value 3 A ● at 220 V rated value 1 A Operating current at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 2 A ● at 110 V rated value 1 A ● at 220 V rated value 0.3 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) Additional Information
UL/CSA ratings Contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection Design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required fuse gL/gG: 250 A — with type of assignment 2 required fuse gL/gG: 160 A ● for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A Installation/ mounting/ dimensions Mounting type screw and snap-on mounting onto 35 mm and 75 mm standard mounting rail ● Side-by-side mounting Yes Height 146 mm Width 70 mm Depth 139 mm Required spacing ● for grounded parts — at the side 6 mm