Rated short-circuit breaking capacity up to 50kA at 220VAC to 240VAC according to Standard EN/IEC 60947-2 and up to 6000A at 230VAC according to Standard EN/IEC 60898-1 Both industrial Standard EN/IEC 60898-1 and residential Complies with standard EN/IEC 60947-2 This miniature circuit breaker protects circuits against short circuit and overload current Unique Visitrip indicator reduces intervention time by indicating the faulty circuit Visisafe green strip ensures physical opening of contacts to allow downstream maintenance Manual quick-shutdown mechanism independent of operation extends service life Electrical withstand up to 10000 cycles and mechanical withstand up to 20000 cycles Rated insulation voltage Ui is 500VAC Limitation class 3 (according to EN/IEC60898-1) increases the cost of downstream circuit protection The product can be clipped to the DIN rail Width 9mm level 2 Overvoltage category IV Product color is white (RAL9003) Dimensions (W) 18mm x (H) 85mm x (D) 78.5mm Weight 0.215kg According to IEC 60529 Standard, degree of protection in the box IP20 and IP40 Operating temperature -35° C to 70°C Storage temperature -40°C to 85°C.
Specifications Main
Main
device application Distribution sherry Act 9 product name Acti9 iC60 Product or component type Miniature circuit breaker Product group IC60N Definition of pole 1P number of protected poles 1 [In] nominal current 3 A Network type AC
DCopening unit technology Thermal Magnetic slope code C cutting capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 220 ...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 60.. .72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2Usage category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2suitability for insulation Yes conforming to TR 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2Standards TR 60898-1
EN 60947-2
IEC 60947-2
IEC 60898-1quality labels NF Complement
Network frequency 50/60Hz magnetic opening limit 8 x In +/- 20% [Ics] nominal service interrupting capacity 50 kA 100 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 - 100 ...133 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
6000 A 100 % conforming to TR 60898-1 - 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 - 72 V DC
10 kA 100 % conforming to IEC 60947-2 - 72 V DC
15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
15 kA 100 % conforming to IEC 60947-2 - 12.. .60V DCrestriction class 3 conforming to TR 60898-1
3 conforming to IEC 60898-1[Ui] nominal insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2[Uimp] rated impulse withstand voltage Conforming to 6 kV EN 60947-2
Conforming to 6 kV IEC 60947-2ignition position indicator Yes Control type Transition On-device signaling Open indicator Mounting Type Still mounting support DIN rail comb busbar distribution block compatibility Top or bottom: YES 9mm screw pitch 2 height 85mm width 18mm Depth 78.5mm Product weight 0.215 kg colour White Mechanical durability 20000 cycles electrical resistance 10000 cycles connections - terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexiblewire stripping length 14 mm for top or bottom connection tightening torque 2 Nm above or below earth leakage protection None Environment and Packing Units
Environment
IP protection degree IP20 conforming to IEC
60529degree of contamination 3 conforming to EN 60947-2
3 conforming to IEC 60947-2overvoltage category IV tropical climate 2 conforming to IEC 60068-1 relative humidity 95% at 55 °C working height 0...2000m Nominal operating ambient temperature -35…70 °C Storage environmental conditions -40…85 °C Packaging units
Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 1.8 cm Package 1 Width 7.5 cm Package 1 Length 9.5 cm Package 1 Weight 112.0g Unit Type of Package 2 BB1 Number of Units in Package 2 12 Package 2 Height 8.0 cm Package 2 Width 10.0 cm Package 2 Length 22.5 cm Package 2 Weight 1,413 kg Unit Type of Package 3 S03 Number of Units in Package 3 132 Package 3 Height 30.0 cm Package 3 Width 30.0 cm Package 3 Length 40.0 cm Package 3 Weight 16,214 kg Contract guarantee
Guarantee properties
iC60N - miniature circuit breaker - 1P - 3A - C curve
A9F74103
Definition of pole:1P
Nominal current (Ir):3 A
slope code:C
- Compliance with industrial insulation according to IEC/EN 60947-2 standard
- Combines short circuit and overload current protection
- Visitrip system for rapid detection of faulty outputs for shorter repair times
- VisiSafe system offering enhanced security when it comes to circuit protection
- Option to add auxiliary devices, remote monitoring and residual current device (Vigi)