This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 11kW / 15hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 6.45kg and its dimensions are, 180mm wide, 232mm high, 170mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
Specifications
| Device short name | ATV212 |
|---|---|
| Product destination | Asynchronous motors |
| Phase | 3 phase |
| Motor power kW | 11 kW |
| Maximum Horse Power Rating | 15 hp |
| Supply voltage limits | 323…528 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Line current | 16.8 A 480 V 21.1 A 380 V |
| Range of Product | Altivar 212 |
| Product or Component Type | Variable speed drive |
| Product Specific Application | Pumps and fans in HVAC |
| communication port protocol | METASYS N2 APOGEE FLN LonWorks BACnet Modbus |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| EMC filter | Class C2 EMC filter integrated |
| IP degree of protection | IP21 |
Specifications Main
Main Device short name ATV212 Product destination Asynchronous motors Network number of phases 3 phases Motor power kW 11 kW Motor power hp 15 hp Supply voltage limits 323…528 V Supply frequency 50...60 Hz - 5...5 % Line current 16.8 A at 480 V
21.1 A at 380 VRange of product Altivar 212 Product or component type Variable speed drive Product specific application Pumps and fans in HVAC Communication port protocol METASYS N2
APOGEE FLN
LonWorks
BACnet
Modbus[Us] rated supply voltage 380...480 V - 15...10 % EMC filter Class C2 EMC filter integrated IP degree of protection IP21 Complementary
Apparent power 17.1 kVA at 380 V Continuous output current 22.5 A at 380 V
22.5 A at 460 VMaximum transient current 24.8 A for 60 s Speed drive output frequency 0.5…200 Hz Speed range 1…10 Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn Local signalling 1 LED (red) for DC bus energized Output voltage <= power supply voltage Isolation Electrical between power and control Type of cable Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVCElectrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14
L1/R, L2/S, L3/T: terminal 16 mm² / AWG 6Tightening torque 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
2.5 N.m, 22 lb.in (L1/R, L2/S, L3/T)Supply Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protectionSampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analogResponse time FM 2 ms, tolerance +/- 0.5 ms for analog output(s)
FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)Accuracy +/- 0.6 % (VIA) for a temperature variation 60 °C
+/- 0.6 % (VIB) for a temperature variation 60 °C
+/- 1 % (FM) for a temperature variation 60 °CLinearity error VIA: +/- 0.15 % of maximum value for input
VIB: +/- 0.15 % of maximum value for input
FM: +/- 0.2 % for outputAnalogue output type FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits
FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bitsDiscrete output type Configurable relay logic: (FLA, FLC) NO - 100000 cycles
Configurable relay logic: (FLB, FLC) NC - 100000 cycles
Configurable relay logic: (RY, RC) NO - 100000 cyclesMinimum switching current 3 mA at 24 V DC for configurable relay logic Maximum switching current 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R)
2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)Discrete input type F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
RES programmable 24 V DC, with level 1 PLC, impedance: 4700 OhmDiscrete input logic Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminalsInsulation resistance >= 1 mOhm 500 V DC for 1 minute Frequency resolution Display unit: 0.1 Hz
Analog input: 0.024/50 HzCommunication service Read holding registers (03) 2 words maximum
Time out setting from 0.1 to 100 s
Write single register (06)
Monitoring inhibitable
Write multiple registers (16) 2 words maximum
Read device identification (43)Additional Information
Option card Communication card for LonWorks Power dissipation in W 430 W Air flow 147 m3/h Functionality Mid Specific application HVAC Variable speed drive application selection Building - HVAC compressor for scroll
Building - HVAC fan
Building - HVAC pumpMotor power range AC-3 7…11 kW at 380…440 V 3 phases
7…11 kW at 480…500 V 3 phasesMotor starter type Variable speed drive Discrete output number 2 Analogue input number 2 Analogue input type VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm
VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bitsAnalogue output number 1 Physical interface 2-wire RS 485 Connector type 1 open style
1 RJ45Transmission rate 9600 bps or 19200 bps Transmission frame RTU Number of addresses 1…247 Data format 8 bits, 1 stop, odd even or no configurable parity Type of polarization No impedance Asynchronous motor control profile Voltage/frequency ratio, 2 points
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Voltage/frequency ratio, 5 pointsTorque accuracy +/- 15 % Transient overtorque 120 % of nominal motor torque +/- 10 % for 60 s Acceleration and deceleration ramps Automatic based on the load
Linear adjustable separately from 0.01 to 3200 sMotor slip compensation Not available in voltage/frequency ratio motor control
Adjustable
Automatic whatever the loadSwitching frequency 6...16 kHz adjustable
12...16 kHz with derating factorNominal switching frequency 12 kHz Braking to standstill By DC injection Network frequency 47.5...63 Hz Prospective line Isc 22 kA Protection type Overheating protection: drive
Thermal power stage: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply overvoltage and undervoltage: drive
Line supply undervoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
With PTC probes: motorWidth 180 mm Height 232 mm Depth 170 mm Net weight 6.45 kg Environment
Pollution degree 2 conforming to IEC 61800-5-1 IP degree of protection IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1
IP20 on upper part without blanking plate on cover conforming to IEC 60529
IP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529
IP41 on upper part conforming to IEC 61800-5-1
IP41 on upper part conforming to IEC 60529Vibration resistance 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27 Environmental characteristic Classes 3C1 conforming to IEC 60721-3-3
Classes 3S2 conforming to IEC 60721-3-3Noise level 51 dB conforming to 86/188/EEC Operating altitude 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
<= 1000 m without deratingRelative humidity 5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3Ambient air temperature for operation -10…40 °C (without derating)
40…50 °C (with derating factor)Operating position Vertical +/- 10 degree Product certifications C-Tick
NOM 117
CSA
ULMarking CE Standards IEC 61800-3 category C2
IEC 61800-3 environments 1 category C2
IEC 61800-3 category C3
IEC 61800-3 environments 1 category C3
IEC 61800-3 environments 2 category C3
UL Type 1
IEC 61800-3 environments 1 category C1
IEC 61800-3 environments 1 category C3
IEC 61800-3 environments 2 category C3
IEC 61800-3 environments 2 category C2
IEC 61800-3
IEC 61800-3 category C2
IEC 61800-3 environments 1 category C1
IEC 61800-5-1
EN 55011 class A group 1
IEC 61800-3 environments 2 category C2
EN 61800-3 category C3
IEC 61800-5-1
IEC 61800-3 environments 2 category C1
IEC 61800-3
IEC 61800-3 environments 1 category C2
IEC 61800-3 environments 2 category C1Assembly style With heat sink Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11Regulation loop Adjustable PI regulator Ambient air temperature for storage -25…70 °C Packing Units
Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 27.000 cm Package 1 Width 30.000 cm Package 1 Length 23.000 cm Package 1 Weight 6.117 kg Unit Type of Package 2 P06 Number of Units in Package 2 10 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 74.170 kg