LC1D50ABD - schneider

IEC contactor, TeSys Deca, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VDC coil, open style

in stock: 2

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Quantity
Only 2 left in stock
  • Specifications Main

    Range TeSys
    TeSys Deca
    Range of Product TeSys Deca
    Product or Component Type Contactor
    Device short name LC1D
    contactor application Resistive load
    Motor control
    utilisation category AC-4
    AC-1
    AC-3
    AC-3e
    Poles description 3P
    [Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
    Power circuit <= 300 V DC
    [Ie] rated operational current 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
    80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
    50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
    [Uc] control circuit voltage 24 V DC
  • Complementary

    Motor power kW 15 kW at 220...230 V AC 50/60 Hz (AC-3)
    22 kW at 380...400 V AC 50/60 Hz (AC-3)
    30 kW at 500 V AC 50/60 Hz (AC-3)
    33 kW at 660...690 V AC 50/60 Hz (AC-3)
    25 kW at 415 V AC 50/60 Hz (AC-3)
    30 kW at 440 V AC 50/60 Hz (AC-3)
    11 kW at 400 V AC 50/60 Hz (AC-4)
    15 kW at 220...230 V AC 50/60 Hz (AC-3e)
    22 kW at 380...400 V AC 50/60 Hz (AC-3e)
    30 kW at 500 V AC 50/60 Hz (AC-3e)
    33 kW at 660...690 V AC 50/60 Hz (AC-3e)
    25 kW at 415 V AC 50/60 Hz (AC-3e)
    30 kW at 440 V AC 50/60 Hz (AC-3e)
    Maximum Horse Power Rating 3 hp at 115 V AC 50/60 Hz for 1 phase motors
    7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
    15 hp at 200/208 V AC 50/60 Hz for 3 phase motors
    15 hp at 230/240 V AC 50/60 Hz for 3 phase motors
    40 hp at 460/480 V AC 50/60 Hz for 3 phase motors
    40 hp at 575/600 V AC 50/60 Hz for 3 phase motors
    Compatibility code LC1D
    Pole contact composition 3 NO
    Protective cover With
    [Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
    80 A (at 140 °F (60 °C)) for power circuit
    Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
    250 A DC for signalling circuit conforming to IEC 60947-5-1
    900 A at 440 V for power circuit conforming to IEC 60947
    Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current 400 A 104 °F (40 °C) - 10 s for power circuit
    810 A 104 °F (40 °C) - 1 s for power circuit
    84 A 104 °F (40 °C) - 10 min for power circuit
    208 A 104 °F (40 °C) - 1 min for power circuit
    100 A - 1 s for signalling circuit
    120 A - 500 ms for signalling circuit
    140 A - 100 ms for signalling circuit
    Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
    100 A gG at <= 690 V coordination type 1 for power circuit
    100 A gG at <= 690 V coordination type 2 for power circuit
    Average impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
    Power dissipation per pole 3.7 W AC-3
    9.6 W AC-1
    3.7 W AC-3e
    [Ui] rated insulation voltage Power circuit 600 V CSA
    Power circuit 600 V UL
    Signalling circuit 690 V IEC 60947-1
    Signalling circuit 600 V CSA
    Signalling circuit 600 V UL
    Power circuit 690 V IEC 60947-4-1
    Overvoltage category III
    Pollution degree 3
    [Uimp] rated impulse withstand voltage 6 kV IEC 60947
    Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    Mechanical durability 10 Mcycles
  • Properties

    Electrical durability 1.45 Mcycles 50 A AC-3 <= 440 V
    0.5 Mcycles 80 A AC-1 <= 440 V
    1.45 Mcycles 50 A AC-3e <= 440 V
    Control circuit type DC standard
    Coil technology Built-in bidirectional peak limiting diode suppressor
    Control circuit voltage limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC
    0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC
    1...1.25 Uc 140…158 °F (60…70 °C) operational DC
    Inrush power in W 19 W 68 °F (20 °C))
    Hold-in power consumption in W 7.4 W 68 °F (20 °C)
    Operating time 50 ±15 % ms closing
    16...24 ms opening
    Time constant 34 ms
    Maximum operating rate 3600 cyc/h 140 °F (60 °C)
    Connections - terminals Control circuit: screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) - cable stiffness: flexible with cable end
    Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) - cable stiffness: flexible with cable end
    Control circuit: screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) - cable stiffness: solid without cable end
    Control circuit: screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) - cable stiffness: solid without cable end
    Power circuit: screw connection 1 0.00…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end
    Power circuit: screw connection 2 0.00…0.04 in² (1…25 mm²) - cable stiffness: flexible without cable end
    Power circuit: screw connection 1 0.00…0.05 in² (1…35 mm²) - cable stiffness: flexible with cable end
    Power circuit: screw connection 2 0.00…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end
    Power circuit: screw connection 1 0.00…0.05 in² (1…35 mm²) - cable stiffness: solid without cable end
    Power circuit: screw connection 2 0.00…0.04 in² (1…25 mm²) - cable stiffness: solid without cable end
    Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
    Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.16 in (4 mm)
    Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hexagonal 0.16 in (4 mm)
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
    Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
    Auxiliary contact composition 1 NO + 1 NC
    Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
    Mirror contact 1 NC IEC 60947-4-1
    Signalling circuit frequency 25...400 Hz
    Minimum switching voltage 17 V for signalling circuit
    Minimum switching current 5 mA for signalling circuit
    Insulation resistance > 10 MOhm for signalling circuit
    Non-overlap time 1.5 ms on de-energisation between NC and NO contact
    1.5 ms on energisation between NC and NO contact
    Mounting Support Plate
    Rail
  • Environment & standard

    Standards CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    IEC 60335-1
    Product Certifications UL
    GOST
    DNV
    LROS (Lloyds register of shipping)
    CCC
    GL
    CSA
    RINA
    BV
    IP degree of protection IP20 front face IEC 60529
    Protective treatment THIEC 60068-2-30
    Climatic withstand IACS E10 exposure to damp heat
    IEC 60947-1 Annex Q category D exposure to damp heat
    Permissible ambient air temperature around the device -40…140 °F (-40…60 °C)
    140…158 °F (60…70 °C) with derating
    Operating altitude 0...9842.52 ft (0...3000 m)
    Fire resistance 1562 °F (850 °C) IEC 60695-2-1
    Flame retardance V1 conforming to UL 94
    Mechanical robustness Vibrations contactor open 2 Gn, 5...300 Hz)
    Vibrations contactor closed 4 Gn, 5...300 Hz)
    Shocks contactor closed 15 Gn for 11 ms)
    Shocks contactor open 10 Gn for 11 ms)
    Height 4.80 in (122 mm)
    Width 2.17 in (55 mm)
    Depth 4.72 in (120 mm)
    Net Weight 2.05 lb(US) (0.93 kg)
    Ordering and shipping details
    Category US10I1222358
    Discount Schedule 0I12
    GTIN 3389119408783
    Returnability Yes
    Country of origin FR
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 2.44 in (6.200 cm)
    Package 1 Width 5.39 in (13.700 cm)
    Package 1 Length 5.98 in (15.200 cm)
    Package 1 Weight 35.24 oz (999.000 g)
    Unit Type of Package 2 S02
    Number of Units in Package 2 10
    Package 2 Height 5.91 in (15.000 cm)
    Package 2 Width 11.81 in (30.000 cm)
    Package 2 Length 15.75 in (40.000 cm)
    Package 2 Weight 22.62 lb(US) (10.260 kg)
No Reviews YetShare your thoughts. Be the first to leave a review.
bottom of page