LC1DT40M7
LC1DT40M7 - scheinder
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 40 A - 220 V AC coil
stock : 18Description
TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 40A/440V AC-1. It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications Main
Main
sherry TeSys
TeSys DecaProduct line TeSys Deca Product or component type Contactor Product group LC1D contactor application Resistance load Usage category AC-1
AC-3
AC-3e
AC-4Definition of pole 4P [Ue] nominal operating voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC[Ie] rated operating current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit [Uc] control circuit voltage 220V AC 50/60Hz Complementary
Compatibility code LC1D pole contact arrangement 4 NA protective cover With [Ith] classical open air thermal current 10 A (at 60 °C) for signaling circuit
40 A (at 60 °C) for power circuitIrms nominal closing capacity 140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 50 A 40 °C - 10 min for power circuit
120 A 40 °C - 1 min for power circuit
240 A 40 °C - 10 s for power circuit
380 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuitrelevant insurance value 10 A gG for signaling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2 mOhm - Ith 40 A 50 Hz for power circuit power distribution per pole 3.2W AC-1 [Ui] nominal insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA certified
Signaling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1overvoltage category III degree of contamination 3 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 security reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1Mechanical durability 15 Mcycles electrical resistance <= 440 V at 1.4 Mcycles 40 A AC-1 Ue control circuit type AC at 50/60 Hz coil technology Without built-in suppressor module control circuit voltage limits 0.3...0.6 Uc -40…70 °C drop AC 50/60 Hz
0.8...1.1 Uc -40…60 °C operation AC 50 Hz
0.85...1.1 Uc -40…60 °C operation AC 60 Hz
1...1.1 Uc 60…70 °C operation AC 50/60 HzTake-off power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)Holding power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)heat distribution 2…3 W at 50/60 Hz Working hours 4...19 msec on
12...22 msec offMaximum operating speed 3600 cyc/h at <60 °C connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible With cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible With cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible With cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible With cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² - cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable endproperties
tightening torque Control circuit: 1.7 Nm - on screw clamp terminals - flat Ø 6 mm with a screwdriver
Control circuit: 1.7 Nm - on screw clamp terminals - with a screwdriver Philips No 2
Control circuit: 1.7 Nm - on screw clamp terminals - with a screwdriver pozidriv No 2
Power circuit: 1.8 Nm - on screw clamp terminals - flat Ø 6 mm with a screwdriver
Power circuit: 1.8 Nm - on screw clamp terminals - with a screwdriver Philips No 2
Power circuit: 1.8 Nm - on screw clamp terminals - with a screwdriver pozidriv No 2auxiliary contact arrangement 1 NA + 1 NC auxiliary contact type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1signaling circuit frequency 25...400Hz minimum switching voltage 17 V for signaling circuit minimum switching current 5 mA for signaling circuit insulation resistance > 10 MOhm for signaling circuit non-overlap period 1.5 ms between NC and NO contact on de-energization
1.5 ms between NC and NO contact on energizationmounting support Rail
PlateEnvironment and Packing Units
Environment
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1Product certificates DNV
GL
CCC
LROS (Lloyds register of shipping)
RINA
BV
GOST
UL
CSA
CBIP protection degree IP20 front face conforming to IEC 60529 preventive maintenance TH conforming to IEC 60068-2-30 climatic resistance IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heatallowable ambient air temperature around the device -40…60 °C
with 60…70 °C deratingworking height 0...3000m fire resistance 850 °C conforming to IEC 60695-2-1 Flame retardant V1 conforms to UL 94 mechanical strength Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms)Height 91mm Width 45mm Depth 99mm Product weight 0.425 kg Packaging units
Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 5,400 cm Package 1 Width 9,400 cm Package 1 Length 12,000 cm Package 1 Weight 467,000g Unit Type of Package 2 S02 Number of Units in Package 2 16 Package 2 Height 15,000 cm Package 2 Width 30,000 cm Package 2 Length 40,000 cm Package 2 Weight 8,019 kg properties 1
- New modern look and feel of all machines
- notification_ok
- Electro is designed to meet the requirements of domestic and HVAC applications.
- Easier to install and operate with multi-standard screws
- IEC60335-1 compliance with improved fire resistance and dustproof aids
- Digital customer experience for technical documentation