LC1DT40M7 - scheinder

TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 40 A - 220 V AC coil

stock : 18

Description

TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 40A/440V AC-1. It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Quantity
  • Specifications Main

     

    Main

    sherry TeSys
    TeSys Deca
    Product line TeSys Deca
    Product or component type Contactor
    Product group LC1D
    contactor application Resistance load
    Usage category AC-1
    AC-3
    AC-3e
    AC-4
    Definition of pole 4P
    [Ue] nominal operating voltage Power circuit: <= 690 V AC 25...400 Hz
    Power circuit: <= 300 V DC
    [Ie] rated operating current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
    [Uc] control circuit voltage 220V AC 50/60Hz
  • Complementary

    Compatibility code LC1D
    pole contact arrangement 4 NA
    protective cover With
    [Ith] classical open air thermal current 10 A (at 60 °C) for signaling circuit
    40 A (at 60 °C) for power circuit
    Irms nominal closing capacity 140 A AC for signaling circuit conforming to IEC 60947-5-1
    250 A DC for signaling circuit conforming to IEC 60947-5-1
    450 A at 440 V for power circuit conforming to IEC 60947
    rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current 50 A 40 °C - 10 min for power circuit
    120 A 40 °C - 1 min for power circuit
    240 A 40 °C - 10 s for power circuit
    380 A 40 °C - 1 s for power circuit
    100 A - 1 s for signalling circuit
    120 A - 500 ms for signalling circuit
    140 A - 100 ms for signalling circuit
    relevant insurance value 10 A gG for signaling circuit conforming to IEC 60947-5-1
    63 A gG at <= 690 V coordination type 1 for power circuit
    40 A gG at <= 690 V coordination type 2 for power circuit
    average impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
    power distribution per pole 3.2W AC-1
    [Ui] nominal insulation voltage Power circuit: 600 V CSA certified
    Power circuit: 600 V UL certified
    Signaling circuit: 690 V conforming to IEC 60947-1
    Signaling circuit: 600 V CSA certified
    Signaling circuit: 600 V UL certified
    Power circuit: 690 V conforming to IEC 60947-4-1
    overvoltage category III
    degree of contamination 3
    [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
    security reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    Mechanical durability 15 Mcycles
    electrical resistance <= 440 V at 1.4 Mcycles 40 A AC-1 Ue
    control circuit type AC at 50/60 Hz
    coil technology Without built-in suppressor module
    control circuit voltage limits 0.3...0.6 Uc -40…70 °C drop AC 50/60 Hz
    0.8...1.1 Uc -40…60 °C operation AC 50 Hz
    0.85...1.1 Uc -40…60 °C operation AC 60 Hz
    1...1.1 Uc 60…70 °C operation AC 50/60 Hz
    Take-off power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
    70 VA 50 Hz cos phi 0.75 (at 20 °C)
    Holding power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
    7 VA 50 Hz cos phi 0.3 (at 20 °C)
    heat distribution 2…3 W at 50/60 Hz
    Working hours 4...19 msec on
    12...22 msec off
    Maximum operating speed 3600 cyc/h at <60 °C
    connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible With cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible With cable end
    Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
    Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end
    Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible without cable end
    Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end
    Power circuit: screw clamp terminals 1 2.5…10 mm² - cable stiffness: flexible With cable end
    Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible With cable end
    Power circuit: screw clamp terminals 1 2.5…16 mm² - cable stiffness: solid without cable end
    Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: solid without cable end
       
  • properties

    tightening torque Control circuit: 1.7 Nm - on screw clamp terminals - flat Ø 6 mm with a screwdriver
    Control circuit: 1.7 Nm - on screw clamp terminals - with a screwdriver Philips No 2
    Control circuit: 1.7 Nm - on screw clamp terminals - with a screwdriver pozidriv No 2
    Power circuit: 1.8 Nm - on screw clamp terminals - flat Ø 6 mm with a screwdriver
    Power circuit: 1.8 Nm - on screw clamp terminals - with a screwdriver Philips No 2
    Power circuit: 1.8 Nm - on screw clamp terminals - with a screwdriver pozidriv No 2
    auxiliary contact arrangement 1 NA + 1 NC
    auxiliary contact type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
    type mirror contact 1 NC conforming to IEC 60947-4-1
    signaling circuit frequency 25...400Hz
    minimum switching voltage 17 V for signaling circuit
    minimum switching current 5 mA for signaling circuit
    insulation resistance > 10 MOhm for signaling circuit
    non-overlap period 1.5 ms between NC and NO contact on de-energization
    1.5 ms between NC and NO contact on energization
    mounting support Rail
    Plate
  • Environment and Packing Units

    Environment

    standards CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    IEC 60335-1
    Product certificates DNV
    GL
    CCC
    LROS (Lloyds register of shipping)
    RINA
    BV
    GOST
    UL
    CSA
    CB
    IP protection degree IP20 front face conforming to IEC 60529
    preventive maintenance TH conforming to IEC 60068-2-30
    climatic resistance IACS E10 exposure to damp heat
    conforming to IEC 60947-1 Annex Q category D exposure to damp heat
    allowable ambient air temperature around the device -40…60 °C
    with 60…70 °C derating
    working height 0...3000m
    fire resistance 850 °C conforming to IEC 60695-2-1
    Flame retardant V1 conforms to UL 94
    mechanical strength Vibrations contactor open (2 Gn, 5...300 Hz)
    Vibrations contactor closed (4 Gn, 5...300 Hz)
    Shocks contactor closed (15 Gn for 11 ms)
    Shocks contactor open (8 Gn for 11 ms)
    Height 91mm
    Width 45mm
    Depth 99mm
    Product weight 0.425 kg

    Packaging units

    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 5,400 cm
    Package 1 Width 9,400 cm
    Package 1 Length 12,000 cm
    Package 1 Weight 467,000g
    Unit Type of Package 2 S02
    Number of Units in Package 2 16
    Package 2 Height 15,000 cm
    Package 2 Width 30,000 cm
    Package 2 Length 40,000 cm
    Package 2 Weight 8,019 kg
  • properties 1

    • New modern look and feel of all machines
    • notification_ok
    • Electro is designed to meet the requirements of domestic and HVAC applications.
    • Easier to install and operate with multi-standard screws
    • IEC60335-1 compliance with improved fire resistance and dustproof aids
    • Digital customer experience for technical documentation