LC1E0910M5 - SCHNEIDER

Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,9A,220V AC coil,50Hz,1NO auxiliary contact

In Stock

Description

EasyPact TVS contactor 3 poles for motor applications up to 9A 4kW@440V. It provides a 220V 50Hz AC coil, 1NO built-in auxiliary contacts, power and control connections by screw clamp terminals. 45mm width for standard operating rates up to 1800 cycles per hour. It procures standard reliability and durability with 1.4 Mcycles electrical durability AC-3 and 10 Mcycles mechanical durability. It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Quantity
  • Specifications

    Range Easy TeSys
    Range of product Easy TeSys Control
    product or component type Contactor
    Device short name LC1E
    contactor application Resistive load
    Motor control
    Utilisation category AC-3
    AC-1
    Poles description 3P
    [Ue] rated operational voltage Power circuit: <= 690 V AC 50/60 Hz
    [Ie] rated operational current 9 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
    25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
    [Uc] control circuit voltage 220 V AC 50 Hz
  • Complementary

    Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
    4 kW at 380...400 V AC 50/60 Hz (AC-3)
    4 kW at 415 V AC 50/60 Hz (AC-3)
    4 kW at 440 V AC 50/60 Hz (AC-3)
    5.5 kW at 500 V AC 50/60 Hz (AC-3)
    5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
    Pole contact composition 3 NO
    [Ith] conventional free air thermal current 25 A (at 55 °C) for power circuit
    Irms rated making capacity 90 A at 440 V AC for power circuit conforming to IEC 60947-4-1
    Rated breaking capacity 72 A at 440 V for power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current 105 A 40 °C - 10 s for power circuit
    61 A 40 °C - 60 s for power circuit
    30 A 40 °C - 600 s for power circuit
    Associated fuse rating 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1
    20 A gG at <= 690 V coordination type 1 for power circuit
    Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
    Power dissipation per pole 0.2 W AC-3
    1.6 W AC-1
    [Ui] rated insulation voltage 690 V conforming to IEC 60947-4-1
    Overvoltage category III
    Pollution degree 3
    [Uimp] rated impulse withstand voltage 6 kV coil not connected to the power circuit conforming to IEC 60947
    Mechanical durability 10000000 cycles
    Electrical durability 1400000 cycles AC-3
    150000 cycles AC-1
    Control circuit type AC at 50 Hz
    Control circuit voltage limits 0.85...1.1 Uc (-5…55 °C):operational 50 Hz
    0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz
    Inrush power in VA 95 VA 50 Hz cos phi 0.75 (at 20 °C)
    95 VA 60 Hz cos phi 0.75 (at 20 °C)
    Hold-in power consumption in VA 8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
    8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
    Heat dissipation 2…3 W for control circuit
    Operating time 12...22 ms on closing
    4...19 ms on opening
    Maximum operating rate 1800 cyc/h 60 °C
  • Environmental

    Standards IEC 60947-5-1
    IEC 60947-4-1
    IEC 60947-1
    Product certifications CE
    EAC
    IP degree of protection IP2X conforming to IEC 60529
    Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30
    Permissible ambient air temperature around the device -20…70 °C at Uc
    -60…80 °C storage
    -5…55 °C operation
    Operating altitude 3000 m without derating
    Fire resistance 850 °C conforming to IEC 60695-2-1
    Mechanical robustness Vibrations contactor open (1.5 Gn, 5...300 Hz)
    Vibrations contactor closed (3 Gn, 5...300 Hz)
    Shocks contactor open (7 Gn for 11 ms)
    Shocks contactor closed (10 Gn for 11 ms)
    Height 74 mm
    Width 45 mm
    Depth 80 mm
    net weight 0.3 kg