LP1K0610BD - SCHNEIDER

Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A, 1 NO aux, 24VDC coil
In Stock

Description

LP1K0610BD is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 24V DC coil and 1NO auxiliary contact allowing easy integration to all control systems. LP1K0610BD is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it can be easily integrated into all control systems thanks to its 24V DC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Ready for connection to all control systems thanks to a 24V DC control voltage and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Quantity
  • Specifications

    Range TeSys
    Product or Component Type Contactor
    Device short name LP1K
    contactor application Motor control
  • Complementary

    Utilisation category AC-3
    AC-3e
    AC-4
    poles description 3P
    power pole contact composition 3 NO
    [Ue] rated operational voltage Power circuit <= 690 V AC <= 400 Hz
    Signalling circuit <= 690 V AC <= 400 Hz
    [Ie] rated operational current 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
    6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
    Control circuit type DC standard
    [Uc] control circuit voltage 24 V DC
    Motor power kW 1.5 kW 220...230 V AC 50/60 Hz AC-3
    2.2 kW 380...415 V AC 50/60 Hz AC-3
    3 kW 440/690 V AC 50/60 Hz AC-3
    1.5 kW 220...230 V AC 50/60 Hz AC-3e
    2.2 kW 380...415 V AC 50/60 Hz AC-3e
    3 kW 440/690 V AC 50/60 Hz AC-3e
    1.5 kW 220...230 V AC 50/60 Hz AC-4
    2.2 kW 380...415 V AC 50/60 Hz AC-4
    3 kW 440/690 V AC 50/60 Hz AC-4
    auxiliary contact composition 1 NO
    [Uimp] rated impulse withstand voltage 8 kV
    Overvoltage category III
    [Ith] conventional free air thermal current 20 A (at 140 °F (60 °C)) for power circuit
    10 A (at 122 °F (50 °C)) for signalling circuit
    Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947
    110 A AC for signalling circuit conforming to IEC 60947
    Rated breaking capacity 110 A at 220...230 V conforming to IEC 60947
    110 A at 380...400 V conforming to IEC 60947
    110 A at 415 V conforming to IEC 60947
    110 A at 440 V conforming to IEC 60947
    80 A at 500 V conforming to IEC 60947
    70 A at 660...690 V conforming to IEC 60947
    [Icw] rated short-time withstand current 90 A 122 °F (50 °C) - 1 s for power circuit
    85 A 122 °F (50 °C) - 5 s for power circuit
    80 A 122 °F (50 °C) - 10 s for power circuit
    60 A 122 °F (50 °C) - 30 s for power circuit
    45 A 122 °F (50 °C) - 1 min for power circuit
    40 A 122 °F (50 °C) - 3 min for power circuit
    20 A 122 °F (50 °C) - >= 15 min for power circuit
    80 A - 1 s for signalling circuit
    90 A - 500 ms for signalling circuit
    110 A - 100 ms for signalling circuit
    Associated fuse rating 25 A gG at <= 440 V for power circuit
    25 A aM for power circuit
    10 A gG for signalling circuit conforming to IEC 60947
    10 A gG for signalling circuit conforming to VDE 0660
    Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
    [Ui] rated insulation voltage Power circuit 600 V UL 508
    Power circuit 690 V IEC 60947-4-1
    Signalling circuit 690 V IEC 60947-4-1
    Signalling circuit 690 V IEC 60947-5-1
    Signalling circuit 600 V UL 508
    Power circuit 600 V CSA C22.2 No 14
    Signalling circuit 600 V CSA C22.2 No 14
    Insulation resistance > 10 MOhm for signalling circuit
    Inrush power in W 3 W 68 °F (20 °C))
    Hold-in power consumption in W 3 W 68 °F (20 °C)
    Heat dissipation 1.3 W
    Control circuit voltage limits Operational: 0.8...1.15 Uc (at <122 °F (50 °C))
    Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
    Connections - terminals Screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid
    screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
    screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end
    screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid
    screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
    screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
    Power circuit screw clamp terminals 2 0.00 in² (1.5 mm²)flexible with cable end
    Maximum operating rate 3600 cyc/h
    Auxiliary contacts type Instantaneous 1 NO
    Minimum switching current 5 mA for signalling circuit
    Minimum switching voltage 17 V for signalling circuit
    Mounting Support Rail
    Plate
    Tightening torque 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2
    7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm
    7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
    Operating time 30...40 ms coil energisation and NO closing
    10 ms coil de-energisation and NO opening
    Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
    Mechanical durability 10 Mcycles
    Electrical durability 1.3 Mcycles 6 A AC-3 <= 440 V
    1.3 Mcycles 6 A AC-3e <= 440 V
    0.05 Mcycles 36 A AC-4 <= 440 V
    Height 2.28 in (58 mm)
    Width 1.77 in (45 mm)
    Depth 2.24 in (57 mm)
    Net Weight 0.50 lb(US) (0.225 kg)
  • Environmental

    Standards EN/IEC 60947-4-1
    EN/IEC 60947-5-1
    UL 60947-4-1
    UL 60947-5-1
    CSA C22.2 No 60947-4-1
    CSA C22.2 No 60947-5-1
    GB/T 14048.4
    Product Certifications CB Scheme
    CCC
    UL
    CSA
    EAC
    CE
    UKCA
    IP degree of protection IP2X
    Ambient air temperature for operation -13…122 °F (-25…50 °C)
    Ambient Air Temperature for Storage -58…176 °F (-50…80 °C)
    Operating altitude 6561.68 ft (2000 m) without derating
    Flame retardance V1 conforming to UL 94
    Requirement 2 conforming to NF F 16-101
    Requirement 2 conforming to NF F 16-102
    Ordering and shipping details
    Category US10I1222321
    Discount Schedule 0I12
    GTIN 3389110363227
    Returnability Yes
    Country of origin US
No Reviews YetShare your thoughts. Be the first to leave a review.