LP1K0910BD - SCHNEIDER

TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil
In Stock

Description

Provides reliability and durability for standard applications for operating rates up to 600 rpm and environments up to 50°C Very compact (45 mm wide), DIN rail mounting or screw fixing Multi standard certified (IEC, UL, CSA, CCC , EAC), Green Premium compliant (RoHS/REACh).

Quantity
  • Specifications

    Range TeSys
    product or component type Contactor
    Device short name LP1K
    contactor application Motor control
    Resistive load
  • Complementary

    Utilisation category AC-3
    AC-3e
    AC-1
    AC-4
    Poles description 3P
    power pole contact composition 3 NO
    [Ue] rated operational voltage Power circuit: <= 690 V AC <= 400 Hz
    Signalling circuit: <= 690 V AC <= 400 Hz
    [Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
    9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
    20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
    Control circuit type DC standard
    [Uc] control circuit voltage 24 V DC
    Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz AC-3
    4 kW at 380...415 V AC 50/60 Hz AC-3
    4 kW at 440/690 V AC 50/60 Hz AC-3
    2.2 kW at 220...230 V AC 50/60 Hz AC-3e
    4 kW at 380...415 V AC 50/60 Hz AC-3e
    4 kW at 440/690 V AC 50/60 Hz AC-3e
    2.2 kW at 220...230 V AC 50/60 Hz AC-4
    4 kW at 380...415 V AC 50/60 Hz AC-4
    4 kW at 440/690 V AC 50/60 Hz AC-4
    auxiliary contact composition 1 NO
    [Uimp] rated impulse withstand voltage 8 kV
    Overvoltage category III
    [Ith] conventional free air thermal current 20 A (at 60 °C) for power circuit
    10 A (at 50 °C) for signalling circuit
    Irms rated making capacity 110 A AC for power circuit conforming to IEC 60947
    110 A AC for signalling circuit conforming to IEC 60947
    Rated breaking capacity 110 A at 220...230 V conforming to IEC 60947
    110 A at 380...400 V conforming to IEC 60947
    110 A at 415 V conforming to IEC 60947
    110 A at 440 V conforming to IEC 60947
    80 A at 500 V conforming to IEC 60947
    70 A at 660...690 V conforming to IEC 60947
    [Icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit
    85 A 50 °C - 5 s for power circuit
    80 A 50 °C - 10 s for power circuit
    60 A 50 °C - 30 s for power circuit
    45 A 50 °C - 1 min for power circuit
    40 A 50 °C - 3 min for power circuit
    20 A 50 °C - >= 15 min for power circuit
    80 A - 1 s for signalling circuit
    90 A - 500 ms for signalling circuit
    110 A - 100 ms for signalling circuit
    Associated fuse rating 25 A gG at <= 440 V for power circuit
    25 A aM for power circuit
    10 A gG for signalling circuit conforming to IEC 60947
    10 A gG for signalling circuit conforming to VDE 0660
    Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
    [Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508
    Power circuit: 690 V conforming to IEC 60947-4-1
    Signalling circuit: 690 V conforming to IEC 60947-4-1
    Signalling circuit: 690 V conforming to IEC 60947-5-1
    Signalling circuit: 600 V conforming to UL 508
    Power circuit: 600 V conforming to CSA C22.2 No 14
    Signalling circuit: 600 V conforming to CSA C22.2 No 14
    Insulation resistance > 10 MOhm for signalling circuit
    Inrush power in W 3 W (at 20 °C)
    Hold-in power consumption in W 3 W at 20 °C
    Heat dissipation 1.3 W
    Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
    Drop-out: >= 0.10 Uc (at <50 °C)
    Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
    Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
    Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
    Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
    Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
    Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
    Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end
    Maximum operating rate 3600 cyc/h
    Auxiliary contacts type Type instantaneous 1 NO
    Minimum switching current 5 mA for signalling circuit
    Minimum switching voltage 17 V for signalling circuit
    Mounting support Rail
    Plate
    Tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
    0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
    0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
    Operating time 30...40 ms coil energisation and NO closing
    10 ms coil de-energisation and NO opening
    Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    Mechanical durability 10 Mcycles
    Electrical durability 1.3 Mcycles 9 A AC-3 at Ue <= 440 V
    1.3 Mcycles 9 A AC-3e at Ue <= 440 V
    0.16 Mcycles 20 A AC-1 at Ue <= 690 V
    0.02 Mcycles 54 A AC-4 at Ue <= 440 V
    Height 58 mm
    Width 45 mm
    Depth 57 mm
    net weight 0.225 kg
  • Environmental

    Standards EN/IEC 60947-4-1
    EN/IEC 60947-5-1
    UL 60947-4-1
    UL 60947-5-1
    CSA C22.2 No 60947-4-1
    CSA C22.2 No 60947-5-1
    GB/T 14048.4
    Product certifications CB Scheme
    CCC
    UL
    CSA
    EAC
    CE
    UKCA
    IP degree of protection IP2X
    Ambient air temperature for operation -25…50 °C
    ambient air temperature for storage -50…80 °C
    Operating altitude 2000 m without derating
    Flame retardance V1 conforming to UL 94
    Requirement 2 conforming to NF F 16-101
    Requirement 2 conforming to NF F 16-102
  • Ordering and shipping details

    Category US10I1222321
    Discount Schedule 0I12
    GTIN 3389110363241
    Returnability Yes
    Country of origin SG