LV429632
SKU: 101
$240.00 Regular Price
$216.00Sale Price
LV429632 - schneider
circuit breaker Compact NSX100F - TMD - 63 A - 3 poles 3d
in stock :3
Explanation
Breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz Operating voltage 690VAC 50/60Hz This product includes a thermal-magnetic trip unit (TMD) rated 63A The TMD trip unit has an adjustable thermal overload protection and a fixed provides magnetic shielding This 3-pole version (105 mm x 161 mm x 86 mm) comes with a variety of optional functions and accessories Complies with international standards (IEC 60947), CCC, EAC and marine specifications Compact NSX100F is part of the Schneider Electric EcoStruxure Power architecture .
Only 3 left in stock
Technicial Specifications Mother
sherry Compact Name of the product Compact NSX Product series ComPact NSX100...250 Product group NSX100F Product or component type Circuit breaker device application Distribution Number of poles 3P protected pole description 3t [In] rated current 63 A at 40 °C [Ue] nominal operating voltage 690V AC 50/60Hz Network type HUNGRY grid frequency 50/60Hz suitability for insulation Yes conforming to EN/IEC 60947-2 usage category Category A [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508
25 kA at 480 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50 /60 Hz conforming to IEC 60947-2Performance level F 36 kA 415 V AC Trip Unit Name TM-D trip unit technology Thermal Magnetic Trip Unit Protection Functions LI Control type Transition Circuit breaker mounting mode Still Complement
[Ui] nominal insulation voltage 800V AC 50/60Hz [Uimp] nominal impulse withstand voltage 8kV [Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2Mechanical durability 50000 cycles electrical durability 10000 cycles at 690 V In
20000 cycles at 690 V In/2
30000 cycles at 440 V In
50000 cycles at 440 V In/2mounting support Back plate top link Front downlink Front connection range 35mm protection type L : for overload protection (thermal)
I : for short circuit protection (magnetic)tripping unit degree 63 A at 40 °C Long-time pick-up adjustment type Ir (thermal protection) Adjustable [Ir] long-time protection pick-up adjustment range 0.7...1 x In Long-time protection delay adjustment type tr Still [tr] long-time protection delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x IrShort-time protection pick-up adjustment type Isd Still [Isd] Short-time protection pick-up adjustment range 500A Short-time protection delay adjustment type tsd Still earth leakage protection None Number of slots for electrical auxiliaries 5 slot(s) Width (W) 105mm Height (H) 161mm Depth(D) 86mm Environment
standards EN/IEC 60947 Product certifications CCC
EAC
Maritimeovervoltage category Class II electric shock protection class Class II degree of pollution 3 conforming to IEC 60664-1 IP protection degree IP40 conforming to IEC 60529 HR protection degree IK07 conforming to IEC 62262 Nominal operating ambient temperature -25…70 °C Storage environmental conditions -50…85 °C relative humidity 0…95% working height 0...2000 m without derating
2000 m...5000 m with derating
No Reviews YetShare your thoughts.